Cue Site Manager / Programmer’s Manual / CSMDataProvider (driver)
© CUE, a.s. All Rights Reserved. | www.cuesystem.com | [email protected]
CSMDataProvider (driver)
Description
This driver provides communication between site application and CSM. It is used in site project and it allows
to collect monitored parameters and start operatore commands.
Requirements
CUEnet connected to LAN for local monitoring
CUEnet connected to WAN via router for remote monitoring. Router WAN port must have xed public IP
address or DNS record.
One unique TCP port dedicated to CSM. Your router must have set routing rule to forward this port to
local IP address of CUEunit, where CSMDataProvider is connected.
CUEunit used as CSMDataProvider Host Unit (controller, touch panel) with wired LAN connection. It is
not recommend to use wireless connection. There must be one free TCP Server channel on this unit.
Conguration
Insert CSMDataProvider driver to the resources of your project and create instance of it in configuration tab
(drag it from resource window and drop it to the configuration tab). Name instance to CSMDataProvider1.
The CSMDataProvider must be connected to the free TcpServer channel on CUEunit (CUE controller or
touchpanel). It is recommended to use CUEunit, which is always on and which has permanent internet
connection.
Properties
Property Name Data Type Allowed Values Default Value Description
Communication
Password Text Max length = 50 Empty Password for secure
connection. The same
password must be set
in CSMDataCollector
for communication
with this site.
Port Long 1 - 65535 8020 TCP Port for CSM
communication
Timeout Time Any positive :10.0 Timeout for connection
with Cue Site Manager
Description
Name Text Max length = 50, can not
be empty
“SiteName” Name of the site
Location Text Max length = 50 Empty Location of the site
Group Text Max length = 50 Empty Site group
Owner Text Max length = 50 Empty Name of the owner of
the room
PhoneNumber Text Max length = 50 Empty Phone number of the
site
Prestige Text Max length = 50 Empty Description of the
prestige
EquipmentList Text Max length = 200 Empty Description of site
equipment list
NumberOfSeats Long Any 0 Number of seats in
case of meeting room
WebControlAddress Text Max length = 50 Empty Address of site control
web pages