Cue sensorCUE-W Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Cue sensorCUE-W. CUE sensorCUE-W User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CUE, a.s., K Nouzovu 6, 143 00 Praha 4, Czech Republic
fax: +420 241 432 446
www.cuesystem.com
mail: info@cuesystem.com
phone: +420 241 091 240
User Manual
sensorCUE-W
Version 01
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - User Manual

CUE, a.s., K Nouzovu 6, 143 00 Praha 4, Czech Republic fax: +420 241 432 446www.cuesystem.commail: [email protected]: +420 241 091 240 User

Page 2 - UM034_01, 19.04.2008

6. Program module for sensorCUE For easier programming you can use the module sensorCUE.csm. You can find it on the CUE Application CD in folder XPL

Page 3 - Table of Contents

7. Specifications and Mechanical Drawings Temperature measurement...Range -20°C to +50°C Daylight sensing ...

Page 4 - 1. Introduction

8. Software and Firmware License END-USER NOTICE AND LICENSE AGREEMENT FROM CUE, a.s. NOTICE TO END-USER: CAREFULLY READ THE FOLLOWING LEGAL AGREEME

Page 5 - 2. Description

Notes User Manual sensorCUE-W www.cuesystem.com Page 13 of 14

Page 6 - 3. Connecting

User Manual sensorCUE-W www.cuesystem.com Page 14 of 14 Notes

Page 7 - 4. Addressing

User Manual sensorCUE-W UM034_01, 19.04.2008 Copyright © CUE, a.s., Praha, Czech Republic 1990 - 2008. All rights reserved. Specifications are subject

Page 8 - 5. Programming

Table of Contents 1. Introduction...

Page 9 - Page 9 of 14

1. Introduction 1.1. Overview... sensorCUE-W is a temperature and daylight sensor fo

Page 10 - Page 10 of 14

2. Description The case of sensorCUE-W is a small plastic box (83 x 81 x 27 mm) which allows simple installation into the standard European electrica

Page 11 - Page 11 of 14

3. Connecting The connection of sensorCUE-W is described in the picture below. Pin12Signal+24GDescriptionPower +24 VDCGroundPhoenix 4-pin 3.5 mm34A+B

Page 12 - Page 12 of 14

4. Addressing Each unit connected to the CUEwire bus must have its unique address. These addresses for touchpanels and keyboards are set in configurat

Page 13 - Page 13 of 14

5. Programming The standard command for reading out the data from sensorCUE-W is: RemoteVariableGet (reference as Word, paneladdress As Byte) as Word

Page 14 - Page 14 of 14

Temperature –Response data relationship: TEMPERATURE RESPONSE VALUE (binary) RESPONSE VALUE (hex) +25.0625°C 0000 0001 1001 0001 0191H +10.125°C 000

Commentaires sur ces manuels

Pas de commentaire